Long-Term cVOC Reduction Downgradient of an S‑MicroZVI Barrier

Case study highlights

Delivered up to 99%+ reductions in key cVOCs approximately 30 feet downgradient of the S-MicroZVI barrier, demonstrating substantial long-term contaminant reduction.

Reduced contaminant concentrations farther downgradient, with PCE, TCE, and cis-1,2-DCE declining approximately 83% to 94% from post-application peaks at a monitoring well 190 feet from the barrier.

Provided sustained treatment beyond the original design horizon, with significant reductions still evident 5.5 years after application compared with a projected treatment longevity of 3 to 5 years.

Addressed a large, fast-moving plume where groundwater velocities reached approximately 400 to 500 feet per year, using strategically positioned treatment zones to reduce source mass and intercept contaminant migration.

Combined complementary remediation technologies to provide contaminant sorption, abiotic reduction, and conditions favorable for biodegradation as part of an integrated approach to plume management.

A large chlorinated solvent plume extending more than 2,000 feet toward a nearby river required a remediation approach capable of controlling contaminant mass and delivering sustained performance. A coordinated REGENESIS remedy using S-MicroZVI and PlumeStop strategically targeted the plume core and intercepted migrating cVOCs. More than five years after installation, monitoring continues to demonstrate substantial concentration reductions, including performance beyond the originally projected treatment period.

Ready to get started?

Our technical experts will work with you to design tailored remediation solutions that effectively address PFAS, chlorinated solvents, and petroleum hydrocarbons—helping you achieve your site goals with confidence.